Frame-free robotic cranial guidance with the Stealth AutoGuide™, StealthStation™ navigation, Midas Rex™ drill, and O-Arm intraoperative CT — for biopsy, sEEG, deep tumour resection, navigated VP shunt placement, and navigated spine surgery at KIMS Neuroscience, Secunderabad, Hyderabad.
Precision in brain surgery is not a luxury — it is a clinical requirement. The targets of complex neurosurgical procedures are often measured in millimetres: a 6 mm thalamic lesion for biopsy, a 3 mm cortical column for sEEG electrode placement, a 5 mm burr hole for a shunt catheter. The instruments used to reach these targets travel 5–10 cm through the brain. A 1° deviation in the entry angle translates to 1–2 mm of positional error at target depth. In critical brain regions — the basal ganglia, the thalamus, the brainstem — a 2 mm error is the difference between a successful procedure and a haemorrhage.
The Stealth AutoGuide™ robotic cranial guidance platform exists to eliminate this positional error. By coupling a robotic arm to the StealthStation navigation system, it mechanically positions the surgical guide at the planned entry point and angle with image-guided targeting, across any trajectory the surgeon chooses, without requiring the bulky rigid stereotactic frame that was the previous standard of care. KIMS is the first hospital in India to have deployed this system.
Speak directly with the KIMS neurosurgical team about how robotic guidance applies to your specific procedure — biopsy, sEEG, deep tumour, shunt, or spine.
040-44885000Email: neuroscience@kimshospitals.comKIMS Hospitals Secunderabad, Hyderabad is the first hospital in India to perform cranial procedures using the Stealth AutoGuide™ Robotic Guidance Platform — a frame-free robotic positioning system that works in tandem with StealthStation™ navigation and Midas Rex™ high-speed drill technology to deliver image-guided targeting for complex cranial procedures. Confirmed clinical outcomes at KIMS: stereotactic biopsy · sEEG electrode placement for epilepsy · deep-seated tumour resection · CSF shunt placement.
The Stealth AutoGuide™ is a robotic arm mounted on the patient’s skull that uses data from the StealthStation™ navigation system to position a surgical guide tube at any planned entry point and trajectory on the skull with image-guided targeting — without the rigid stereotactic frame previously required for stereotactic procedures. The robot does not operate autonomously; it positions the instrument guide so that the neurosurgeon can execute the planned trajectory that freehand positioning cannot consistently achieve.
| Fact | Details |
|---|---|
| The physics | 1° angle deviation at entry = 1-2mm error at depth · In thalamus/basal ganglia/brainstem: 2mm = haemorrhage risk · AutoGuide constrains guide tube mechanically to planned trajectory, eliminating angular deviation |
| 4-step workflow | Planning (StealthStation) → Registration (1-2mm guidance) → AutoGuide arm positioning (2-3 min/trajectory vs 10-15 min frame) → Procedure through guide tube |
| Stereotactic biopsy | 95-98% diagnostic yield · <1% haemorrhage requiring treatment · <1-2% neurological deficit · Tissue for IDH, MGMT, 1p/19q, BRAF, and other molecular markers |
| sEEG for epilepsy | 8-15 electrodes per session · Within 2-3mm of planned target · 2-3 min per electrode (vs 10-15 min frame) · Standard tool for epilepsy surgery at KIMS |
| VP shunt placement | Freehand malposition: 20-30% · AutoGuide: near-zero · Particularly valuable for slit ventricles and previous shunt failure anatomy |
| O-Arm spine | 13-second 3D CT acquisition · Auto-fused to StealthStation · Confirms pedicle screw position before wound closure |
| Emergency | 040-46324365 (24×7) for sudden neurological deficit after any guided procedure |
The Stealth AutoGuide combined with StealthStation and O-Arm enables six distinct surgical capabilities at KIMS — cranial and spinal — each described in clinical detail in the sections below.
Robotic arm mounted on the skull, integrated with StealthStation navigation, positions a guide tube at any planned trajectory with <1 mm guidance — without the rigid Leksell frame.
Sub-millimetre trajectory accuracy for deep, eloquent, or small lesions where tissue is essential for diagnosis. Haemorrhage requiring treatment <1%; neurological deficit <1–2%.
Depth electrodes implanted through small burr holes to within 2–3 mm of the planned target — recording from inside the brain over 1–2 weeks. Standard tool in epilepsy surgery at KIMS.
Small burr hole + tubular retractor or laser fibre passed to deep targets (thalamus, basal ganglia, insula, pineal region) along an AutoGuide-planned trajectory — avoiding the brain retraction of open craniotomy.
AutoGuide positions the ventricular catheter in slit-like ventricles or scarred post-failure anatomy — reducing the 20–30% freehand malposition rate to near zero.
Real-time 3D CT fused with StealthStation for pedicle screw trajectory, MISS, percutaneous screws, lateral fusions, and spine tumour separation surgery — with intraoperative screw-position confirmation before closure.
The AutoGuide workflow proceeds in four sequential steps — from pre-operative planning through to the procedure executed through the locked guide tube.
The day before or the morning of surgery, the surgeon opens the patient's MRI on the StealthStation workstation and plans the procedure in detail. For a biopsy: the target point (the lesion) and the entry point on the skull are defined, and the software calculates the optimal straight-line trajectory that avoids blood vessels, ventricles, and critical structures along the path. For sEEG: multiple trajectories (typically 8–15 electrodes) are planned simultaneously, each with its own entry point and target depth electrode tip position. For shunt placement: the ventricular catheter tip target position in the lateral ventricle is defined. The planning software models the trajectory in 3D and displays every critical structure along the path.
The patient's head is registered to the navigation coordinate system using the StealthStation probe and anatomical landmarks (or pre-placed fiducial markers). This links the 3D coordinate system of the surgical plan to the physical position of the patient's head in the operating room. Registration accuracy: typically 1–2 mm from the planned target, verified by touching a known anatomical landmark with the navigated probe and confirming it coincides with the expected MRI position.
The Stealth AutoGuide arm is mounted on the patient's skull (attached to the Mayfield head clamp or a skull-mounted base). The surgeon selects the planned trajectory on the StealthStation workstation. The AutoGuide arm automatically moves to position its guide tube at exactly the planned skull entry point, at exactly the planned angle — in all three spatial planes simultaneously. The surgeon verifies the position by viewing the alignment on the StealthStation screen, then locks the arm in place. The entire positioning sequence takes approximately 2–3 minutes per trajectory, versus 10–15 minutes for conventional frame-based stereotaxy.
With the AutoGuide arm locked in position at the planned trajectory, the surgeon performs the procedure through the guide tube: a small burr hole is made through the guide tube with the Midas Rex™ drill system · The biopsy needle, sEEG electrode, shunt catheter, or laser fibre is passed through the guide tube to the planned depth · Real-time tracking on the StealthStation confirms the instrument's depth and position relative to the target as it advances. The guide tube constrains the instrument to the planned trajectory throughout its travel, eliminating the freehand angular deviation that accumulates over the length of the needle path.
Stereotactic biopsy obtains diagnostic brain tissue from lesions that are: too deep or too eloquent to resect safely · Too small for open surgery · In a location where the diagnosis is unclear and tissue is essential for treatment planning (lymphoma vs glioma vs metastasis vs infection). At KIMS, the Stealth AutoGuide system has been used for biopsy of deep-seated tumours including thalamic lesions, brainstem lesions, and deep white matter lesions. The robotic guide positions the biopsy needle at the planned trajectory with image-guided targeting, maximising the probability of representative diagnostic tissue and minimising the risk of haemorrhage from off-trajectory passage through vascular structures. Diagnostic yield: published studies report that stereotactic biopsy provides a diagnosis in most cases. (Published data; results vary.) Complication rate: haemorrhage requiring treatment <1%; neurological deficit from biopsy <1–2%.
sEEG is the most advanced intracranial EEG technique for localising the seizure onset zone in patients with drug-resistant epilepsy who are being evaluated for resective surgery. Multiple depth electrodes (8–15 or more) are implanted through the skull into specific cortical and subcortical targets to record electrical activity from inside the brain over 1–2 weeks of monitoring, capturing seizures as they begin and spread. Each electrode is a 0.8 mm diameter flexible shaft with multiple contacts along its length, placed to a planned depth in a specific brain region of interest. The precision requirements: each electrode tip must land within 2–3 mm of the planned target to record from the intended cortical layer. A 3 mm error in a thalamic electrode is the difference between recording hippocampal seizure onset and recording uninvolved posterior temporal lobe activity. At KIMS, the Stealth AutoGuide system is used for sEEG implantation: each trajectory is planned on the StealthStation, the AutoGuide positions the guide tube for each electrode in sequence, and the electrodes are implanted one by one through the guide. For a 12-electrode implant, the total procedure time using AutoGuide is significantly shorter than frame-based approaches, with equivalent or superior guidance. At KIMS, sEEG is part of the pre-surgical evaluation pathway for complex epilepsy cases.
For tumours in deep brain locations (thalamus, basal ganglia, insula, pineal region) that cannot be reached by a direct open craniotomy without traversing significant functional brain tissue, the AutoGuide system plans a minimally disruptive approach trajectory: a small burr hole at the optimal skull entry point · A tubular retractor or laser fibre passed to the target along the planned trajectory · Resection or ablation performed through the tube. This minimally invasive approach to deep tumours — enabled by AutoGuide targeting — is an alternative to conventional open craniotomy for selected cases where a transcortical tubular approach is clinically appropriate. At KIMS, this technique has been applied to deep-seated tumours where direct open surgery would require excessive brain retraction or cortical sacrifice.
VP shunt placement — inserting a catheter into the lateral ventricle to drain CSF in hydrocephalus — appears simple but has a significant malposition rate when performed without image guidance: approximately 20–30% of freehand shunt catheters are suboptimally positioned on post-operative imaging, contributing to shunt malfunction. The AutoGuide system is used at KIMS for navigated shunt placement in patients where: the ventricles are small or slit-like (making freehand catheter placement blind and unreliable) · Previous failed shunts require catheter placement in a scarred, distorted ventricular system · The clinical situation demands first-attempt guidance. The planned catheter tip position (typically the frontal horn of the lateral ventricle, anterior to the choroid plexus) is defined on MRI, the AutoGuide positions the guide at the correct entry point and trajectory, and the catheter is passed to the planned depth. This approach reduces malposition rates to near zero.
The comparison below contrasts the AutoGuide robotic platform with traditional Leksell frame-based stereotaxy across the practical and clinical dimensions used in surgical planning.
Feature
Stealth AutoGuide™ (Frameless Robotic)
Traditional Leksell Frame (Frame-Based)
No — frame-free positioning
Yes — metal frame screwed to skull under LA
High — no frame worn for hours
Lower — frame in place for 2–4 hours
Yes — planned sequentially, no re-registration
Limited — re-planning required for each trajectory
≈2–3 minutes
≈10–20 minutes (frame arc adjustment)
<1 mm error at target
<2 mm error (frame) · comparable with skilled use
Native — same platform
Requires separate registration
Yes — optimal
Yes — but slower and more cumbersome
Yes — well tolerated without frame
More difficult — frame uncomfortable for long procedures
KIMS Hyderabad
Available at multiple centres
Pedicle screws are the fundamental fixation element of spinal instrumented fusion surgery — used for spondylolisthesis, spinal fractures, deformity correction, and tumour reconstruction. The pedicle is a narrow bony bridge connecting the vertebral body to the posterior elements, through which the screw must pass. A malpositioned pedicle screw can penetrate the pedicle cortex and injure the adjacent nerve root (causing radiculopathy) or the spinal cord (causing paraplegia). Conventional freehand pedicle screw placement using anatomical landmarks and X-ray fluoroscopy has a malposition rate of approximately 10–15% in standard cases and significantly higher in complex deformity. At KIMS, pedicle screw placement in complex cases is performed using O-Arm intraoperative CT imaging integrated with StealthStation navigation: the O-Arm acquires a real-time 3D CT of the operative spine · This is automatically fused with the StealthStation navigation · The planned screw trajectory is displayed on the navigation screens as the surgeon advances the screw · Screw position is confirmed intraoperatively with another O-Arm acquisition after placement, before the wound is closed. This eliminates the need for post-operative revision surgery for malpositioned screws.
Navigation-guided MISS at KIMS uses the StealthStation and O-Arm system to enable precise minimally invasive spinal procedures through small incisions: MIS-TLIF (transforaminal lumbar interbody fusion): navigated disc access and pedicle screw placement through tubular retractors with small skin incisions · Less muscle damage · Shorter hospital stay · Faster recovery than open fusion. Percutaneous pedicle screw placement: screws placed through separate stab incisions without exposing the spine, using navigated fluoroscopy and O-Arm confirmation · Used for minimally invasive stabilisation of fractures and deformity. Navigation-guided lateral approaches (XLIF/DLIF): O-Arm imaging confirms disc space position and implant placement during lateral lumbar interbody fusion. At KIMS, the O-Arm and StealthStation provide the imaging guidance that makes MISS technically reliable across a range of lumbar and thoracic spine procedures.
For spinal tumours — metastatic deposits in the vertebral body, primary bone tumours of the spine, and intradural spinal tumours — navigation is used at KIMS to: plan the extent of vertebral resection required for tumour removal · Guide the reconstruction with interbody cages and pedicle screw fixation · Confirm the completeness of tumour removal and implant position intraoperatively. O-Arm-navigated separation surgery (removing tumour adjacent to the spinal cord to create a circumferential margin for stereotactic body radiotherapy) has become the standard approach at KIMS for metastatic spinal cord compression in patients with radioresistant tumours.
The Stealth AutoGuide and O-Arm navigation systems at KIMS are deployed across cranial and spinal procedures to deliver guidance that unaided human positioning cannot consistently achieve. The following points summarise the most clinically significant facts every patient and referring physician should know.
KIMS Hyderabad is the first hospital in India to perform cranial procedures using the Stealth AutoGuide™ Robotic Guidance Platform
AutoGuide pairs with StealthStation™ navigation and Midas Rex™ high-speed drill — image-guided targeting across any planned skull entry point
Frame-free positioning: ~2–3 minutes per trajectory vs 10–15 minutes for traditional Leksell frame-based stereotaxy
Confirmed clinical applications at KIMS: stereotactic biopsy · sEEG electrode placement · deep-seated tumour resection · CSF shunt placement
Stereotactic biopsy with robotic guidance: 95–98% diagnostic yield · <1% haemorrhage requiring treatment · <1–2% neurological deficit
Each sEEG electrode tip must land within 2–3 mm of its planned target — 0.8 mm diameter flexible shafts placed at depth in specific cortical and subcortical regions
Freehand VP shunt catheter malposition rate is 20–30% — navigated AutoGuide placement reduces this to near zero
Freehand pedicle screw malposition is 10–15% in standard cases; O-Arm + StealthStation navigation enables intraoperative confirmation before closure — eliminating revision surgery
Explore related neuronavigation, robotic, and neurosurgical pages at KIMS Neuroscience:
Where Robotic Cranial Guidance Came to India First — Stealth AutoGuide at KIMS Hyderabad.
A brain biopsy that needs to land within 2 mm of a 6 mm thalamic target. Twelve sEEG electrodes implanted in one session, each within 1 mm of its planned position. A pedicle screw confirmed in real-time before the wound is closed. These are the standards of guidance that the Stealth AutoGuide and O-Arm navigation systems deliver at KIMS Hyderabad — where robotic cranial guidance came to India first. Call 040-44885000.